datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Sanyo Sanyo DP50741 P50741-01 J4JF [SM]

Sanyo Sanyo DP50741 P50741-01 J4JF [SM] free download

Computer monitors - CRT, TFT, LCD, touch screen, plasma display - service manuals and repair information

File information:
File name:Sanyo_DP50741_P50741-01_J4JF_[SM].pdf
[preview Sanyo DP50741 P50741-01 J4JF [SM]]
Size:4841 kB
Extension:pdf
Mfg:Sanyo
Model:Sanyo DP50741 P50741-01 J4JF [SM] 🔎
Original:Sanyo DP50741 P50741-01 J4JF [SM] 🔎
Descr: Sanyo Monitor Sanyo_DP50741_P50741-01_J4JF_[SM].pdf
Group:Electronics > Computer equipment > Monitors
Uploaded:17-02-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name Sanyo_DP50741_P50741-01_J4JF_[SM].pdf

DP50710-00 / 01 DP50740-00 / 02 / 03 DP50741-01 with panel # MD-50H13NBE Suggestions The Pwr Bd. is seldom bad. If the Pwr LED is turning OFF in 4-5 sec., these are the most common failures on the SC & SS Bds., If any are shorted, please replace the board. SC D451 D481 Q661 Q401 Q402 Q421 Q422 SS Q001 Q002 Q021 Q022 SANYO: DP50740-00 / 02 / 03 & DP50710-00 / 01 & DP50741-01 12/28/10 with PANASONIC 50" PLASMA PANEL (MD50H13NBE) p#1 SYMPTOM: TV's GREEN POWER LED WILL NOT REMAIN ON 2010-9B note: Unplugging any power cable from the SMPS to isolate the defective PCB will not work on this Panasonic panel. Unplugging any of the power cables will cause the SMPS to shut down. a) Unplug LVDS Cable (40 pin connector) from Main to Digital "D" Bd. (D5 connector) behind Main: This will eliminate the Main Bd., and see if the SMPS will power ON automatically, and remain ON. Plug the AC Cord to power (do not push the Pwr Key on the TV) and see if the SMPS will power ON. If the SMPS powers ON and remains ON, then the Main Bd. should be tried. If the SMPS continues to shutdown then resistance checks (#1-#12) below should be done. note: This panel has a self test mode, and unplugging the LVDS starts the self test. No raster is displayed, because a special jig is needed to activate the raster & video. RESISTANCE CHECKS TO POSSIBLY ISOLATE DEFECTIVE PCB Location of connectors is 1) Is pin #1 or #2 (55-60V) of (P35 connector) shorted to chassis Gnd? on page #2 yes, shorted = PDP Panel N/G not shorted = go to step #2 Please re-install all PCB mounting 2) Is Pin #5 (5V) of (P25 connector) shorted to chassis Gnd? screws whenever a board is yes, shorted = go to step #3 changed, and before re-testing not shorted = go to step #4 the TV. The ground screws are 3) Disconnect (p25 connector) needed to prevent damage to the Is Pin #5 (5V) of (P25 connector) shorted to chassis Gnd? PCB. yes, shorted = SMPS N/G not shorted = go to step #4 After working on TV, if it has 4) Disconnect (SC20 connector) several horizontal lines or bars, Is pin #30 (5V

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Sanyo Sanyo DP42647 P42647-00 N4VE [SM] - Sanyo Sanyo DP50741 P50741-04 J4JEG [SM] - Sanyo Sanyo DP32640 P32640-11 N8LA [SM] - Sanyo Sanyo DP42840 P42840-05 N7AP [SM] - Sanyo Sanyo DP39842 P39842-04 Z6SJ [SM] - Sanyo Sanyo DP42849 P42849-02 N7AJ [SM] - Sanyo Sanyo DP52440 P52440-02 N7KFF [SM] -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Philips L01.2E

script execution: 0.02 s